{"id":148,"date":"2021-05-25T08:24:00","date_gmt":"2021-05-25T08:24:00","guid":{"rendered":"https:\/\/palladiumss.com\/blog\/?p=148"},"modified":"2024-09-25T09:55:10","modified_gmt":"2024-09-25T09:55:10","slug":"kitchen-hood-fire-suppression-system-inspection","status":"publish","type":"post","link":"https:\/\/palladiumss.com\/blog\/kitchen-hood-fire-suppression-system-inspection\/","title":{"rendered":"Kitchen Hood Fire Suppression System Inspection"},"content":{"rendered":"\n<span style=\"font-weight: 400;\">Fire is the major threat to any place, in particular, the kitchen. The kitchen is a high-heat environment with no small risk, and mostly it is designed to be well-insulated. Especially commercial kitchens are pretty insulated to keep the required heat for cooking. <\/span>\n\n                            <p><br><span style=\"font-weight: 400;\">But the problem is over time; the commercial kitchen can catch up with grease and grime and present new problems to the kitchen hood fire suppression system. Grease and grime stick to the nozzles and disperse your fire suppression agent, and thus it disables the system&#8217;s ability to suppress and extinguish the kitchen fires. And this may cause serious fire accidents. So it is important to maintain your kitchen&#8217;s fire suppression system.\u00a0<\/span><\/p><\/br>\n\n                          \n<span style=\"font-weight: 400;\">So in this article, we will be discussing what kind of inspections your kitchen fire suppression system needs and how you can prepare your restaurant or commercial kitchen for these inspections.\u00a0<\/span>\n<p><br><h3><b>How Often Should the Kitchen Hood Fire Suppression System be Inspected?<\/b><\/h3><\/p><\/br>\n<span style=\"font-weight: 400;\">According to NFPA 96, the kitchen hood fire suppression system inspection must be done every six months. And importantly, the inspection must be done by a licensed fire protection company.<\/span>\n\n<span style=\"font-weight: 400;\">The inspector who does the inspection checks the following,<\/span>\n\n<span style=\"font-weight: 400;\">Whether<\/span>\n\n<span style=\"font-weight: 400;\">There was a fire in your kitchen, and your fire suppression system works properly, i.e., activates and puts off fire successfully when shutting off the gas or electricity that powers your equipment.\u00a0<\/span>\n<h3><strong>What is Done in the Kitchen Hood Fire Suppression System Inspection?<\/strong><\/h3>\n<span style=\"font-weight: 400;\">First, the inspector will check whether the fire suppression system is working as expected and replace any faulty or old parts.\u00a0<\/span>\n\n<span style=\"font-weight: 400;\">Some common tasks that the inspector does are:<\/span>\n<ol>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">All the <a href=\"https:\/\/www.palladiumss.com\/fire-extinguishers\">extinguishing agent<\/a> nozzles would be discharged and inspected<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Replace the nozzle caps<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Extinguisher lines are blown out through the air to ensure that there is no blockage.<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Test the gas shut off valve<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check for holes in hoods<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Manual alarm pull station is checked for its functioning<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Fusible links of the system are cut to if the system starts properly<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The gas and electrical shut off is checked when the system activates<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ensure the proper working of the cartridge<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Once the <a href=\"https:\/\/www.palladiumss.com\">kitchen hood suppression system<\/a> is activated, the inspector will replace the fusible links with new ones with the date stamped on them so that it would serve as proof of service for fire marshal inspection.<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">After complete checking, the inspector will tag the system showing certification was successfully completed by a professional<\/span><\/li>\n \t<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Finally, you will get a commercial cooking system service and inspection report, and it will be sent to your local fire department.\u00a0<\/span><\/li>\n<\/ol>\n<span style=\"font-weight: 400;\">Once this kitchen hood suppression is done, your commercial kitchen will be set for another six months. So apart from the monthly visual inspections, the system will meet the fire requirements, and it will remain safe until your next inspection.\u00a0<\/span>\n\n<br>\n<br>\n<b> Also read :<a href=\"https:\/\/palladiumss.com\/blog\/benefits-of-installing-fire-sprinklers-in-residential-and-commercial-buildings\/\">Benefits of Installing Fire Sprinklers in Residential and Commercial Buildings<\/a> <\/b>\n<br>\n<br>\n\n\n<h3><b>How Should You Prepare Your Kitchen Before the Kitchen Hood Fire Suppression System?<\/b><\/h3>\n<span style=\"font-weight: 400;\">If the kitchen hood fire suppression system has been scheduled, then you need to do the following:<\/span>\n<ul>\n \t<li><span style=\"font-weight: 400;\">Thoroughly clean your kitchen hood\u00a0<\/span><\/li>\n \t<li><span style=\"font-weight: 400;\">Know when the inspection will start<\/span><\/li>\n \t<li><span style=\"font-weight: 400;\">Prepare the kitchen for the inspection<\/span><\/li>\n<\/ul>\n<span style=\"font-weight: 400;\">And that&#8217;s it. I hope this quick blog sounded interesting. Cheers!<\/span>\n","protected":false},"excerpt":{"rendered":"<p>Fire is the major threat to any place, in particular, the kitchen. The kitchen is a high-heat environment with no small risk, and mostly it is designed to be well-insulated. Especially commercial kitchens are pretty insulated to keep the required heat for cooking. But the problem is over time; the commercial kitchen can catch up [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":149,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19],"tags":[11,21,4,3,7,17],"class_list":["post-148","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fire-sprinkler-system","tag-essential-fire-safety","tag-fire-alarm-system","tag-fire-safety-inspection","tag-fire-safety-solution","tag-fire-safety-system","tag-fire-sprinkler-system"],"_links":{"self":[{"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/posts\/148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/comments?post=148"}],"version-history":[{"count":3,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/posts\/148\/revisions"}],"predecessor-version":[{"id":778,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/posts\/148\/revisions\/778"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/media\/149"}],"wp:attachment":[{"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/media?parent=148"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/categories?post=148"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/palladiumss.com\/blog\/wp-json\/wp\/v2\/tags?post=148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}